Transmitter
|
Power Supply
|
AC100-240V 50/60HZ 0.6AMax
|
|
Power Supply
|
Built-in rechargeable battery, continuous working time over 12 hours
|
|
Output
|
OCT frequency output, RS232, data storage
|
|
Error
|
±1.0% R(flow velocity >0.5 m/s)
|
|
±0.005 m/s (flow velocity〈 0.5 m/s
|
|
Sensitivity
|
Can measure extremely low flow, with a limit flow velocity of 0.01m/s
|
|
Repeatability
|
0.1%
|
|
Dimensions and Weight
|
Dimensions (mm): 100×204×34 Weight (kg): 〈 0.5
|
|
Sensor
|
Pipe Diameter Specification
|
(Small diameter) 20mm~40mm (Standard diameter) 40mm~1000mm (Large diameter) 1000mm~4500mm (K-type circular clamped sensor) 20mm~50mm
|
|
Sensor Temperature
|
Standard -40℃~121℃; High temperature -40℃~250℃
|
|
Sensor Type
|
K-type, small diameter type, standard diameter type, large diameter type, high temperature type
|
|
Pipe Material
|
Requires dense, good sound conduction
|
|
Dimensions and Weight
|
Small size (mm): 42×25×25 Weight (kg/pair): 〈 0.2Standard size (mm): 60×43×43 Weight (kg/pair): 〈 0.5Large size (mm): 80×53×53 Weight (kg/pair): 〈 1.0
|
|
Accessories and Options
|
Injection-molded Portable Case
|
1 piece
|
|
Couplant
|
1 piece
|
|
Elastic Straps
|
4 pieces
|
|
Charger
|
1 piece
|
|
Data Storage
|
Optional 512M - 8GB SD card
|
|
Software
|
Data Storage Supporting Software
|